Features and main functions of high-voltage resonance test equipment
1) The interior of the high-voltage resonance test device is controlled by an embedded touch screen, with optimized operating functions and simple operation
2) Automatically sweep the frequency to find the resonance point. The frequency range is 20-300 Hz, and the sweep range can be manually set. The sweep takes up to 1.5 minutes (full frequency sweep). The frequency resolution is 0.01 Hz
3) Automatic test, the user can set the test program, the system automatically completes the test process according to the set program
4) When the high-voltage resonance test device is automatically tested, it automatically tracks the resonance state of the system. When the resonance state changes and exceeds the set area, the system automatically tracks the resonance point
5) Automatically track the voltage when withstand voltage, and automatically adjust the voltage to the target voltage when the voltage fluctuates normally, and the user will operate according to the test situation
6) Full voltage output protection: During the voltage regulation process, strictly ensure that the variable frequency power supply will not output full voltage
7) The software has undergone strict simulation operation inspection
8) Automatically save test data, data query function, query past test data according to query conditions
9) The LCD screen of the high-voltage resonance test device can display the power supply voltage and current; the frequency, voltage, and current of the high-voltage output
10) Protection function: with power failure, over current, over voltage and flashover protection functions;
Over-current protection: The over-current protection value can be manually set; when the output current of the entire device reaches the protection setting value, the entire device is automatically cut off
Breakdown protection: With discharge or flashover protection function, when a flashover to ground occurs on the high-voltage side, the whole set of equipment is automatically cut off. Will not cause harm to the test equipment and human body, and the electronic components in the variable frequency power supply will not breakdown
Power failure protection: After the test power is cut off, the device can quickly protect
11) After the internal structure of the variable frequency power supply and its components are transported through normal roads and railways, the mutual position remains unchanged, no damage, and no loose fasteners.
12) The appearance and operation interface fully adopt the humanized design, which is beautiful and easy to operate