The technical specifications of the main components of series resonance are as follows:

(1) Frequency conversion control unit

Input working power: 220V, 50Hz, current 5~250A

Output voltage and current: 0~250V, current 5~250A

Output frequency: 20~300Hz,

Frequency adjustment fineness: 0.1Hz

Large output power: 5~10000kVA

(2) Excitation transformer

Input working power: 250V current 5~250A

Output voltage and current: 0~10kV, current 1~10A

Rated capacity: 5~50000kVA

(3) Resonant reactor: (technical specification of each resonator)

Rated working voltage of a single reactor: 20kV, 40kV, 60kV (effective value)

Single rated working current: 1~10A (effective value)

(4) Capacitor voltage divider

Working method: pure capacitive

Rated voltage: 20kV, 60kV, 100kV, 200kV, 500kV, 1000kV effective value

Working frequency: 30~300Hz

Measurement error: <1%

Capacitance: 1000pF±5%

Voltage divider low voltage arm: 100V