Welcome to visitWuhan Xinshengneng Technology Co., Ltd.
  • Withstand voltage test equipment

  • High voltage test equipment such as transformers and switches

  • Oil and gasification test equipment

  • Relay protection and secondary circuit test equipment

  • Live and online monitoring equipment

  • Electricity inspection power metering equipment

  • Insulation tool test equipment and battery

  • Others

  • High voltage integrated equipment series

  • SF6 gas test equipment series

  • Insulating appliance series

  • Marketing measurement test equipment series

  • Series resonance

    110kV switch bus series resonance

    Views:

    ●Product introduction
    Product specifications: XSN (XZ) -270kVA/270kV (frequency conversion)
    Applicable test products: busbar switch, substation system, main transformer, cable
    The scope of tested products: 110kV and below voltage level switches, GIS (7 bays) and other substation equipment, 110kV/63000kVA main transformer fully insulated AC withstand voltage test

    ●Product role and function:

    1. Help customers to achieve preventive AC withstand voltage test and handover AC withstand voltage test of various tested products;
    2. Test cross-linked rubber-plastic power cables, power transformers, GIS, transformers, insulators, generators, switches and other test products insulation withstand various overvoltage capabilities and AC withstand voltage test for capacitive loads.

    Product nicknames: series resonance withstand voltage test equipment, AC withstand voltage test equipment, resonant booster device for inspection, series resonance withstand voltage tester.

    Test object: 1. AC withstand voltage test of 110kV and below voltage level switches, GIS (7 intervals) and other substation equipment, test frequency 30-300Hz, test voltage not exceeding 265kV, test time 1min.

    2. AC withstand voltage test of 110kV/63000kVA main transformer full insulation, capacitance ≤0.02uF, test frequency 45-65Hz, test voltage not exceeding 160kV, test time 1min.

    3. AC withstand voltage test of 1km of 35kV/300mm2 cable, capacitance ≤0.1945uF, test frequency 30-300Hz, test voltage not exceeding 52kV, test time 60min.

    4. AC withstand voltage test of 110kV/300mm2 cable 0.2km, capacitance ≤0.029uF, test frequency 30-300Hz, test voltage not exceeding 128kV, test time 60min.

    5. AC withstand voltage test of 10kV/300mm2 cable 3km, capacitance≤1.1265uF, test frequency 30-300Hz, test voltage not exceeding 22kV, test time 5min.

    ●Technical parameters
    1. Product core parameters:
         Rated capacity: 270kVA;
         Input power: single-phase 220 or three-phase 380V voltage, frequency is 50Hz;
         Rated voltage: 90kV; 135kV; 270kV;
         Rated current: 3A; 2A; 1A;
         Working frequency: 30-300Hz;
         Device output waveform: sine wave
         Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
         Working time: allow continuous 60min under rated load; overvoltage 1.1 times 1 minute;
         Temperature rise: the temperature rise after 60 minutes of continuous operation under rated load is           ≤65K;
         Quality factor: the device itself Q≥30 (f=45Hz);
         Protection function: Overcurrent, overvoltage and test product flashover protection for the tested product      (see the frequency conversion power supply section for details);
         Measurement accuracy: system effective value 1.5;

    2. Excitation transformer JLB-15kVA/4/8/16kV/0.4kV 1 set
         Rated capacity: 15kVA;
         Input voltage: 0-400V, single phase;
         Output voltage: 4/8/16kV
         Structure: dry type;
         Weight: about 58kg;

    3. Inverter power supply BP-15kW/220/380V 1 unit
         Rated output capacity: 15kW
         Working power supply: 220/380±10%V (single/three-phase), power frequency
         Output voltage: 0 -400V, single phase,
         Rated input current: 37.5A
         Rated output current: 37.5A
         Voltage resolution: 0.01kV
         Voltage measurement accuracy: 1.5%
         Frequency adjustment range: 30 – 300Hz
         Frequency adjustment resolution: ≤0.1Hz
         Frequency stability: 0.1%
         Running time: continuous 60min under rated capacity
         The maximum temperature of the components during continuous operation for 60min under the rated           capacity is ≤65K;
         Noise level: ≤50dB

    4. High-voltage reactor DK(G)-45kVA/45kV Section 6
         Rated capacity: 45kVA;
         Rated voltage: 45kV;
         Rated current: 1A;
         Inductance: 110H/single section;
         Quality factor: Q≥30 (f=45Hz);
         Structure: dry type;
         Weight: about 45kg;

    5. Capacitor voltage divider FY-270kV/500pF 1 set
         Rated voltage: 270kV;
         High voltage capacity: 500pF
         Dielectric loss: tgσ≤0.5%;
         Partial pressure ratio: 3000:1
         Measurement accuracy: effective value 1.5;
         Weight: about 26kg

    Back To Top
    Copyright © Wuhan Xinshengneng Technology Co., Ltd. All Rights Reserved  鄂ICP备2020019985号-1   Web site productionsanjin.net