Product name: Water-cooled DC high voltage generator
Product specifications: XSN-ZGF-S
Product introduction:
1. Because the windings of large water-cooled generators conduct a large current, the test voltage ranges from about 20-150mA. If there is no DC high voltage generator with sufficient capacity, the voltage cannot be boosted.
2. At present, the output current of the domestic DC high voltage tester is generally within 10mA, and the high voltage generator with an output current of 200mA is blank.
3. For general high-voltage electrical equipment, the DC test can find the penetration defect of its insulation, and for the motor, it can find its partial insulation defect (insulation at the end of the stator coil), which cannot be replaced by other tests. .
4. In order to accurately measure the leakage current of the internal water-cooled generator set, the 60kV/200mA series of internal water-cooled DC high-voltage generators are specially designed to compensate for various interference currents. The stray current and the poles of the collecting pipe can be completely eliminated during the test. The current of the test product is actually measured under the influence of chemical potential interference.
Product nicknames: direct high-voltage generator, high-voltage generator, intermediate frequency DC high-voltage generator.
Test object:
The 60kV/200mA series water-cooled DC high-voltage generator adopts intermediate frequency voltage doubler circuit. Apply new PWM pulse width modulation technology and high-power IGBT devices. According to the electromagnetic compatibility theory, special shielding, isolation and grounding measures are adopted. The water-cooled DC high voltage generator realizes high quality, portable and can withstand the rated voltage discharge without damage.
technical parameter: