    XSN (XZ) -44kVA/44kV frequency conversion series resonance test device

    Views:

    ● Product Introduction

    Product specifications: XSN (XZ) -44kVA/44kV(frequency conversion)

    Applicable to test products: cable, main transformer, switch cabinet, insulator

    Range of tested products: 10kV/300mm2 cable 1km, 10kV/6300kVA main transformer, 10kV switch cabinet, insulator

    ● Product functions and functions:

    1. Help customers to carry out preventive ac pressure test and handover AC pressure test of various tested products;

    2. Ac voltage withstand test of cross-linked rubber and plastic power cables, power transformer, GIS, transformer, insulator, generator, switch and other tested products' insulation ability to withstand various overvoltages and capacitive loads.

    ● Product name:

    Series resonance withstand voltage test complete set, AC withstand voltage test complete set, resonance boost device for inspection, series resonance withstand voltage tester.

    ● Test object:

    1, 10kV/300mm2 cable length 1km AC voltage test, capacitance ≤0.3755uF, test frequency 30-300Hz, test voltage 22kV, test time 5min.

    2. Ac voltage withstand test of 10kV/6300kVA main transformer, capacitance ≤0.01uF, test frequency 45-65Hz, test voltage 35kV, test time 1min.

    3. Ac voltage withstand test of 10kV switchgear and insulator, test frequency 30-300Hz, test voltage 42kV, test time 1min.

    ● Technical parameters

    Capacity: 80kVA;

    Rated voltage: 160kV;

    Single reactor: 80kVA/160kV;

    Working voltage: 220V/380±10%, power frequency;

    Resonant voltage waveform: pure sine wave;

    Working time: continuous operation for 5 minutes at full power output;